Name: 
 

Fiber U Loss and Power Budgets



True/False
Indicate whether the statement is true or false.
 

 1. 

Loss budgets calculate the loss of the entire cable plant and all its components including the connectors on each end of the cable plant.
 

 2. 

A fiber optic link can have high BER (bit error rate) if the receiver power is either too high or too low.
 

 3. 

Industry standards have component losses higher than typically expected in the real world.
 

 4. 

If you test a  fiber in a cable plant that has a loss budget of 7.5dB and get test results of 7.7dB loss, you should reject that fiber.
 

 5. 

Power budget specs for network equipment links are generally conservative becasue the output of transmitters and sensitivity of receivers varies from unit to unit.
 

Multiple Choice
Identify the choice that best completes the statement or answers the question.
 

 6. 

A fiber optic link may have high bit-error rate if ____________.
a.
Receiver power is too high
b.
Receiver power is too low
c.
Receiver power is either too high or too low
 

 7. 

The calculated loss budget can be used as a reference value for testing as well as a check to see if the system will operate over the cable plant being designed, but one needs to allow for a measurement uncertainty of _______ when setting PASS/FAIL limits.
a.
+/- 0.05-0.10 dB
b.
+/- 0.2-0.5 dB
c.
+/- 0.5-1.0 dB
d.
>1 dB
 

 8. 

If a transmitter has an output of +1dBm and it’s companion receiver needs at least -13dBm to work, what is the power budget of this link?
a.
12dB
b.
14dB
c.
10dB
d.
Need specs of connectors and splices to calculate it
 

 9. 

A multimode premises cable has a length of 150m, two intermediate connections as well as connections on each end. If the fiber attenuation coefficient is 3dB/km at 850nm and connections have a loss of 0.5dB, what is the loss budget for this cable?  (Feel free to use the FOA Loss Calculator online)
a.
1.45dB
b.
5.0dB
c.
2.90dZZZB
d.
2.45dB
 

 10. 

A intercity cable plant is 40km long. with 10 splices and connections on ly on the ends. If fiber attenuation coefficient is 0.4dB/km at 1310nm and 0.2dB/km at 1550nm, splices are 0.15dB and connections 0.3dB, what is the loss of the cable plant at 1310nm. (Feel free to use the FOA Loss Calculator online)
a.
10.1dB
b.
18.1dB
c.
17.5dB
d.
13.3dB
 

 11. 

The communications equipment available for use on the intercity cable plant described above has two options - 1310nm or 1550nm, both of which have a 13dB Power budget. Which one should be chosen for the link.
a.
1310nm equipment
b.
1550nm equipment
 

 12. 

The difference between the power budget of the network equipment and the loss budget of the cable plant is called the link ________.
a.
Margin
b.
Excess power
c.
Aging constant
d.
Gravy
 

Multiple Response
Identify one or more choices that best complete the statement or answer the question.
 

 13. 

When calculating a loss budget, one may use values for component loss  _________.
 a.
Specified by industry standards
 b.
Estimated values of typical installed losses
 c.
Values specified by the customer
 d.
Values specified by the component manufacturer
 

 14. 

The loss budget for the liber is calculated by multiplying the _________ by the __________ of the fiber.
 a.
Attenuation coefficient
 b.
Loss
 c.
Length
 d.
Bandwidth
 

 15. 

The loss budget calculated at the design stage of a project is used to ___________>
 a.
Select the proper fiber type for the cable plant
 b.
Determine if the communications network will work on the cable plant
 c.
Compare to test results to verify proper installation
 d.
Verify the cable plant is designed to the proper standards
 



 
Check Your Work     Start Over