1.
|
FTTO and passive OLANs generally use _______ connectors which are color-coded
_____________.
A. | Singlemode, beige | B. | Singlemode PC, beige | C. | Singlemode APC,
Green | D. | Any, blue |
|
|
2.
|
Connectors on reference patchcords for testing OLAN singlemode cable plants must
match the type of connector used on the cable plant, e.g. APC.
|
|
3.
|
FTTD (contralized fiber) links using MM fiber should be tested at
_________nm.
A. | 850 | B. | 1300 | C. | 1310 | D. | 1310 and 1490 |
|
|
4.
|
FTTO links using SM fiber should be tested at _________nm with a
_____source.
A. | 850, VCSEL | B. | 1300, LED | C. | 1310,
laser | D. | 1310 and 1490, laser |
|
|
5.
|
The loss budget for a fiber optic cable plant includes __________.
A. | The loss of the total length of fiber | B. | The loss of all connectors and
spices | C. | The loss of any passive devices like splitters | D. | All of
these |
|
|
6.
|
Passive OLANs transmit at 1310nm upstream and 1490nm downstream. Since most
singlemode sources have 1310 and 1550nm lasers, it is acceptable to test at 1550nm instead of
1490nm.
|
|
7.
|
OTDR testing of passive optical LANs can be tricky because of
__________.
A. | The short lengths of cable in passive OLANs may be less than the OTDR's
resolution | B. | Splitters have different traces upstream and downstream and may be hard to
interpret | C. | OTDRs will not find installation-caused stress points if the cables use
bend-insensitive fibers | D. | All of these |
|